1. Low to near zero background for assured indication visibility.
2. Sharp, precise flaw indication for rapid interpretation.
3. Excellent electrostatic spray capability.
4. Long material tank life due to formula stability and non-volatility.
5. Low material consumption (low drag out) due to low viscosity.
6. Clean, odorless product, vapor free atmosphere.
7. Water base penetrant with no flash point.
Note: These instructions describe the basic process, but they may need to be amended by
the user to comply with applicable specification and/or inspection criteria provided by the contracting agency.
1. Application: Apply WB-100 only to clean, dry surfaces by spraying, flowing, brushing or dipping.
2. Dwell Time: A 10 minute dwell time is suggested, although in many cases five minutes will suffice. When particularly tight cracks are suspected, or the part is especially critical, the dwell time may be extended to 30 minutes, or longer. Allow the penetrant to drain from the part surface back into the penetrant tank to conserve material.
3. Removal:
a) Use ambient temperature water to rinse WB-100 from the part surface. To avoid washing entrapped penetrant from surface flaws, do not use high water pressure or temperatures and avoid prolonged washing times.
b) Solvent Wipe Method - Remove as much excess penetrant as possible using clean dry rag or toweling. Remove remaining penetrant film by wiping with a rag or toweling that has been slightly moistened with solvent. Use a minimum of solvent; avoid flushing penetrant from flaws. Do not spray solvent directly on the part surface when removing excess
penetrant. Rough surfaces require more generous application of solvent.
4. Drying: A re-circulating oven set no higher than 1600F (710C) is suggested. Leave the part in the oven just long enough to evaporate surface moisture. Drying is improved by using pressurized air to disperse and remove as much excess water as possible before placing the part in to the oven.
5. Developing: Apply the developer by cloud, dusting, spray or dip using the appropriate developer. Flaw marks are visible under black light almost immediately, but allow sufficient developing time to enhance the flaw visibility.
6. Inspection: Inspect parts under appropriate UV-A light intensity and minimal visible
light.
Health & Safety
WB-100 is a combustible liquid. Use with adequate ventilation and away from sparks, fire or open flames. Avoid prolonged or repeated contact with skin. Do not take internally.
Consult the MSDS for more safety and health information.